HOSPITAL
                                                                            Water quality regulations /                    SOLUTIONS


            DELABIE’S SPECIFIC ADVANTAGES

            DELABIE is particularly concerned with the fight   Thermostatic mixing valves
            against, and prevention of, bacterial development.  To reduce the risk of bacterial development
            The company is constantly developing new products   (Legionella etc.) public buildings should distribute hot
            with unique features.                      water at temperatures of at least 55°C in healthcare
                                                       facilities (50°C in other non-domestic buildings).
            Adapted water controls                     To reduce the risk of scalding, all DELABIE’s
            DELABIE offers water controls with low water   thermostatic mixing valves are fitted with special
            volumes which have smooth surfaces in            safety devices.                     TEMPOMATIC MIX 4
            contact with the water, and removable               They are supplied with a maximum   Automatic duty flush
            mixers and taps, fitted with flexible   DELABIE’s       temperature limiter pre-set at the   Reduced-stagnation
            hoses or tails, with reduced water    electronic controls    factory.                solenoid valve
            passages in order to reduce the                          The PREMIX NANO thermostatic
            risk of bacterial development   are unique in being able    mixing valve allows the facilities
            considerably.                      to guarantee a          manager to maintain temperatures
            For more information see                                   that comply with the regulations
            page 10.                         regular and               while ensuring user safety.
                                        complete renewal               For more information see
            Electronic controls                                        page 101.
            DELABIE’s models are            of the water
            programmed with a periodic     in all the internal parts.   Scalding can also be prevented
            duty flush.                                               at the point-of-use itself thanks
            An automatic flush takes place   Required by the standard EN 806 5  to the SECURITHERM range of   BIOCLIP
            every 24 hours after the last use                      mixers and shower panels.     Removable mixer
            to prevent water stagnation and,
            therefore, bacterial proliferation.               PREMIX NANO and SECURITHERM
                                                       thermostatic mixers ensure that the hot water supply
            Similarly, DELABIE has developed a reduced-  shuts off if the cold water supply fails.
            stagnation solenoid valve (patented).
            Unlike all other available models which have areas of   WC systems with direct flush and no cistern
            permanent water stagnation, the water is completely   The insides of toilet cisterns are covered in biofilm.
            renewed inside DELABIE’s solenoid valve.   The large surface area of cisterns, and water
            For more information see page 28.          stagnation, make the cistern a major risk factor for
                                                       the proliferation of bacteria that can spread in
            Thanks to these characteristics, DELABIE’s   sanitary installations.
            electronic controls are the only ones to guarantee   By removing the need for toilet cisterns, DELABIE’s   PREMIX NANO
            a regular and complete renewal of the water in all   direct flush systems eliminate the risk of bacterial   Maintains the temperature
            the internal parts, avoiding any risk of bacterial   proliferation.                  in the system
                                                                                                 Anti-scalding failsafe
            proliferation. They are therefore the only ones which   For more information see pages 144 - 151.
            comply with the European standard EN 806 5.

                                                          Cistern-less WC flush systems
                                                            no water stagnation
                                                            no bacterial development




                                                                                                 TEMPOFLUX 3
                                                                                                 Direct flush with no cistern


            Reduced-stagnation solenoid valve






















                                                                                                 Hospital solutions  9
   6   7   8   9   10   11   12   13   14   15   16