Page 12 - Water_Controls_for_Healthcare
P. 12

/ DELABIE’s solutions for infection control


                                   DELABIE’S SOLUTIONS
                                   FOR INFECTION CONTROL

                     BIOSAFE
                                   THE BIOSAFE CONCEPT

                                   Pseudomonas aeruginosa mostly contaminates   Mixers and taps with smooth interiors
                                   mixers and taps at the outlet, i.e. inside the spout.   All the internal parts of certain DELABIE mixers
                                   As a result, this part of the mixer/tap should be the   and taps are completely smooth, reducing biofilm
                                   subject of special attention in order to limit bacterial   attachment and making it easier to treat.
                                   development. To this end, DELABIE has designed   A study by the BioPI laboratory and the Department
                                   specialist controls that facilitate preventative action   for Biological Studies at Jules Verne University
                                   and, if necessary, curative action if contamination   in Amiens, France showed that under constant
                                   occurs.                                    conditions, mixers and taps with smooth interiors
                                                                              have Pseudomonas aeruginosa contamination levels
                                   BIOCLIP removable mixers and taps          14 times lower than those mixers and taps with
                                   for cleaning/disinfection                  rough bodies.
                                   The BIOCLIP range of mixers and taps can be
               After 2 years of use
                                   fitted with specialist spouts and the whole interior   Electronic controls with duty flush programme
                                   can be cleaned - the only way to eliminate biofilm   To overcome water stagnation in water systems, all
                                   completely - helping to fight effectively against   DELABIE’s electronic controls are programmed with
                                   bacterial development.                     a periodic duty flush to prevent bacterial proliferation.
                                   • Mixers with removable BIOCLIP spouts     An automatic flush takes place for ~60 seconds
                                    Mixers are supplied with two stainless steel/brass   every 24 hours after the last use (programmable
                                    spouts. The second spout ensures continuous use while    on some models). As a result, bacteria do not have
               After 10 years of use                                          the opportunity to develop.
                                    the first is being cleaned. Alternative options are:
                                    - Disposable spouts: each spout must be replaced
                                     periodically, depending on the type of installation.  Water controls without non-return valves
              Inside a mixer where there are    - BIOFIL filtration spouts: these spouts guarantee    Cross flow between DHW/DCW is impossible
              no cleaning protocols in place  the bacteriological quality of the water.  DELABIE has developed a unique, patented
                                                                              mechanism for its thermostatic mixers which closes
                                   • BIOCLIP removable mixers                 the Hot and Cold Water directly at the inlets, meaning
                                    Mixers that can be completely removed from their   there is no need for non-return valves. The risk of
                                    base for curative or preventative measures    cross flow is eliminated.
                                    in healthcare facilities:                 See opposite for more information.
                                    - Curative action: bacteriological monitoring
                                     in healthcare environments sometimes requires   BIOSAFE hygienic outlet
                                                                                              ®
                                     remedial action. If mixers and taps are contaminated   Made from Hostaform , its smooth internal surface
               Biofilm is eliminated  by Legionella spp. or Pseudomonas aeruginosa,   provides nowhere for impurities or scale to adhere
               Mixer is like new     they can be easily removed by maintenance staff   reducing the emergence and spread of bacteria
                                     to enable the interior to be completely cleaned.   and germs in damp conditions.
              Inside a mixer where there are                                  It can only be installed on a mixer or tap that already
              regular cleaning protocols in place  - Preventative action: to minimise the risk
                                     of bacterial proliferation in mixers and taps,   has a restricted flow rate to ensure a good flow
                                     DELABIE recommends concentrating         with no splashing.
                                     on preventative measures.                For more information see page 98.
                                   BIOCLIP mixers and taps allow healthcare facilities    BIOFIL point-of-use filtration
                                   to establish regular cleaning protocols (from every    BIOFIL anti-Legionella and all-germ filters guarantee
                                   6 months to every 2 years depending on the type    bacteriologically controlled water at the point-of-use
                                   of facility) to eliminate biofilm and bacteria.
                                                                              and protect the user’s well-being.
              Low volume of standing water  Mixers and taps with low volume   Each BIOFIL filter incorporates a hollow fibre
                                   of standing water                          membrane with a water filtration threshold of
                                   Some of DELABIE’s mixers have specifically designed   0.1 micron nominal-rated. They deliver water free from
                                   interiors that reduce the volume of standing water   microorganisms, providing total protection against
                                   in the body, and thus significantly reduce the risk    waterborne infection.
                                   of bacterial development.                  The BIOFIL range includes tap and wall-mounted
                                                                              shower filters, shower head filters and spout filters.
                                                                              For more information see pages 23 - 25.



              Discover our BIOSAFE
              solutions video











              10  Hospital solutions
   7   8   9   10   11   12   13   14   15   16   17