Page 92 - Water_Controls_for_Public-Commercial
P. 92

/ SPORTING 2 SECURITHERM thermostatic electronic shower panels


                               SPORTING 2 ELECTRONIC SECURITHERM SHOWER PANEL:
                               THE ANTI LEGIONELLA SOLUTION

                               Preventative anti-legionella solution     Anti-scalding failsafe
                               The Health and Safety Executive's guidance HSG 274   SECURITHERM thermostatic technology ensures
                               Part 2 (2014) recommends maintaining the hot water   automatic shut-off if the cold water fails.
                               temperature permanently above 50°C at all points   As such, the SPORTING 2 SECURITHERM has no risk
                               in the system in order to prevent any risk of Legionella   of scalding.
                               bacteria proliferation.
          Hygiene and infection control                                  Comfort
                               Water must be mixed as close as possible to   • Temperature stability
                               points-of-use. The SPORTING 2 SECURITHERM   The SPORTING 2 panel delivers water
                               is the solution to preventing the risk of bacterial   at a stable temperature, even in the event
                               proliferation.
                                                                           of pressure variations.
                                                                         • Cold shower prevention
                               Hygiene                                     SECURITHERM thermostatic technology ensures
                               The thermostatic mixer is integrated in the head    automatic shut-off if the hot water fails.
                               of the SPORTING 2 SECURITHERM panel.
                               Circulating hot water from the system is mixed    Multiple installation options
                               with cold water directly at the point-of-use.  The panel exists in 2 versions:
                               There is therefore no mixed water between   - exposed water inlets, for connection in front of
                               the circulating loop and the point-of-use,
                                                                           the wall, from above,
          Anti-scalding safety  which significantly reduces the risk of bacterial   - recessed water inlets for connection from behind
                               development.
                                                                           the wall from above or below.
          Multiple installation options  The electronic SPORTING 2 has an anti-bacterial
                               duty flush programme.                      30-year warranty against any manufacturing
                               An automatic flush takes place for approximately    defects.
                               60 seconds every 24 hours after the last use,    50 years repairability.
                               therefore avoiding water stagnation in the pipework.
                               The SPORTING 2 SECURITHERM ensures a shower
                               without bacteria.




          Exposed water inlets






                                ANTI LEGIONELLA SOLUTION: SIMPLE AND LOOKS GOOD





          Recessed water inlets
          from below                         HOT WATER LOOP > 50°C


                                               HOT WATER                              COLD WATER
                                                    INLET                             INLET



                                                                                       Water mixed in the
                                                                                      SPORTING 2 SECURITHERM head:
                                          Thermostatic mixer                          as close as possible
                                       directly at the point of use                   to the hot water loop
          Recessed water inlets
          from above



                                    No mixed water circulation                        MIXED WATER OUTLET ~38°C
                                            inside the panel:
                                     limits bacterial development






          90  Showers