Page 97 - Water_Controls_for_Public-Commercial
P. 97

Time flow shower panels /


        HYGIENE                                   EXCEPTIONAL WATER
        AND INFECTION CONTROL                     AND ENERGY SAVINGS: 80%

        Automatic timed shut-off, with no manual contact  Exceptional water savings
        Time flow shower panels shut off automatically once   Compared to conventional showers, time flow shower
        the push-button has been pressed and the valve has   panels can offer maximum water savings. They ensure
        opened.                                   the manager’s water bills can be reduced whilst
        No manual contact after washing prevents the spread   preserving user comfort.
        of germs by hand.                         • Automatic shut-off and split delivery
                                                    The time flow is automatic and shuts off after   Hygiene and infection control
        Thermal shocks                              approximately 30 seconds of flow.
        With SECURITHERM technology, it is possible    Time flow panels remove the risk of waste through
        to undertake thermal shocks without removing    negligence. The flow time is reduced to
        the panel. Simply press the red button with a pointed   the necessary minimum (wetting, rinsing).
        tool to override the maximum temperature limiter.
                                                  • Flow rate 6 lpm
                                                    The time flow shower panels are regulated
                                                    at 6 lpm. The flow rate remains constant regardless
        DESIGN                                      of pressure variations in the system.                             SHOWERS

        Commercial environments and design        Energy savings
        DELABIE’s products, known for their endurance    DELABIE’s time flow shower panels operate
        and reliability, have a timeless design.  completely autonomously with no need for an electrical   Optimised time flow
        The diversity of the product range fits in perfectly    supply. They do not consume any power at all.
        with any commercial installation.         The significant hot water savings provided by
        In an office building or a shopping centre,    the shower panels also result in energy savings.
        it is paramount that the product design fits in
        with its surroundings. In prison, products must   Ecological
        be resistant and secure: concealed mechanisms,   DELABIE’s shower panels are made from materials
        streamlined design, etc.                  that are 100% recyclable which ensures that
                                                  the products receive the best ecological assessment
        Design without constraints                in their category.
        Aesthetic products are subject to less vandalism
        as they are better respected.             Environmental labels
        The smooth shape of the showers reduces the build-up   The water and energy saving performance    Conventional   DELABIE
        of dirt and facilitates cleaning.         of the shower panels means that buildings achieve    shower  panel
        Easy but secure access to the control mechanisms   the highest performance standards    15 lpm   6 lpm
        provides easy maintenance.                for international rating schemes such as LEED,   0%    80%
                                                  BREEAM or HQE.
                                                  For more information see page 8.








                                                                                                 60L     12L

                                                                                                4 min.   2 min.
                                                                                             Water savings per use
                                                  COMPARISONS OF WATER CONSUMPTION
                                                  Comparison between a conventional shower and a DELABIE time flow panel
                                                                                                        Water
                                                   Flow rate   Wetting      Soaping        Rinsing
                                                                                                      consumption
                                                                                                        60L
                                                                   1 min.        2 min.         1 min.
                                                     15L                                                4 min.



                                                                   2 x                         2 x      12L
                                                      6L          30 sec.                     30 sec.   2 min.










                                                                                                    Showers  95