Page 141 - Water_Controls_for_Public-Commercial
P. 141

Point-of-use filters /


        MANAGING WATERBORNE                       BIOFIL FILTERS PERFORMANCE
        HEALTH RISKS

        Water, essential for hygiene, can also be a source    Hollow fibre filter
        of infection if its quality is not controlled.   Each BIOFIL filter incorporates a hollow fibre
        The proliferation of bacteria (Legionella,   membrane with a water filtration threshold
        Pseudomonas aeruginosa, etc.) in the water supply    of 0.1 micron absolute-rated. They deliver water
        or in mixers and taps may cause serious infections,   free from microorganisms (bacteria, protozoa, fungi,
        especially for vulnerable people.         particles in water systems...) without changing    Bacteriologically controlled water
        Water systems in all buildings open to the public should   its chemical composition.
        be monitored for Legionella i.e. swimming pools,   They provide total protection against waterborne
        leisure centres, hotels and holiday accommodation,   infection.
        campsites, medical social care and social care
        establishments, spaces for disabled people, prisons, etc.  Larger filtration area than flat membrane
                                                  The filtration area is substantially
        This applies in all circumstances where the Health    larger in BIOFIL filters with hollow fibre    Filter   Hollow
                                                                                                           fibres
                                                                                             unit
        and Safety at Work Act 1974 - which imposes    membranes than it is in flat membranes.
        the monitoring of the bacteriological quality of water   This large filtration area allows a larger volume   Resin     SHOWERS
        in sanitary installations - applies.      of water to be filtered. Consequently the storage
        The prevention of health risks associated with   capacity for bacteria and impurities trapped inside
        pathogenic bacteria in water systems should be    the filter is much greater.
        a constant concern for public buildings.                                             Section of the BIOFIL tap filter
        The BIOFIL range of point-of-use filters is a   Reduced risk of premature clogging
        preventative or curative solution to secure the water   Articles in suspension stay on the surface of the
        quality at the point-of-use and protect the health of   hollow fibre membrane which delays clogging.
        the user.                                 The large capacity of the storage area means that the
                                                  membrane's lifespan is longer.

                                                  Extremely compact filters
        AREAS OF USE                              Unlike other point-of-use filters on the market, BIOFIL
                                                  filters are smaller due to the compact nature of
        Anti-Legionella and all-germ filters       the fibre. They are suitable for most water controls
        Non-sterile BIOFIL filters are CE marked class I   on the market.                     Tilted to optimise the position
        Medical Devices. Sterile BIOFIL filters are CE marked                                 of the tap filter
        class Is Medical Devices.
        In public and commercial places, they protect users   MANUFACTURING PROCESS
        from the risk of Legionella and provide immediate
        compliance with standard regulations. They are   IS MONITORED CONSTANTLY
        suitable for all types of buildings open to the public
        for the following usage: body hygiene, hand-washing   100% quality controlled
        and balneotherapy.
                                                  The fibre quality and porosity of the finished product
        BIOFIL filters can be installed on the compromised   are continuously monitored during the manufacturing
        point-of-use (basin or shower). They filter water   process for 100% of the fibres.
        directly at the point-of-use ensuring the water is free
        from bacteria.
                                                  COMPONENT DISPOSAL                         CE marked class I Medical
                                                                                             Devices for non-sterile filters
                                                  STRATEGY                                   CE marked class Is Medical
                                                                                             Devices for sterile filters
        CHEMICAL FREE                             BIOFIL filters are classified as household waste.
                                                  The outer packaging is made from recycled
                                                  cardboard which is also fully recyclable.
        No chemicals are used in the making of our filters.


         THE INSTANT BIOFIL SOLUTION

         Mixer or tap can be used immediately after
         installation of the filter.

















                                                                                                    Showers  139