Page 37 - Water_Controls_for_Healthcare
P. 37

Mixers for washbasins /


            ANTI SCALDING SAFETY                       BIOSAFE: INFECTION CONTROL

            Maximum temperature limiter                BIOCLIP removable mixers                          BIOSAFE
            All DELABIE's mixers are supplied with a pre-set   for cleaning/disinfection
            maximum temperature limiter. The user cannot   Since they are in contact with water, the internal
            increase the temperature above the maximum set   surfaces of mixers and taps are exposed to bacterial
            temperature, reducing the risk of scalding.  proliferation.
                                                       The mixers in the BIOCLIP range provide simple
            Automatic anti-scalding failsafe           solutions to fight against the spread of germs inside
            • SECURITHERM thermostatic technology ensures   and on the outside of mixers and taps, and against
             immediate hot water (HW) shut-off if the cold water   the spread of infectious bacteria by hand.             MIXERS & TAPS   FOR WASHBASINS
             (CW) supply fails. If the CW supply fails,    They allow the interior to be cleaned completely
             the European standard EN 1111 allows a slight leak   - the only way to remove biofilm effectively - and
             of HW (0.10L/10 seconds).                 an easy way to disinfect the mixer, for preventative
             With DELABIE's thermostatic mixers the HW    or curative reasons, to fight against bacterial
             shut-off is complete (with no trickle of water).   development effectively.
             If the HW supply fails, DELABIE's SECURITHERM
             mixers also shut off the CW supply.       Body with smooth interior
            • SECURITHERM pressure-balancing technology,   Most mixers and taps have bodies and spouts with
             known as EP, ensures instant and automatic safety.   rough interiors. As a result, they provide niches where
             If the CW supply fails, the HW flow rate is reduced,   bacteria can adhere.          Maximum temperature limiter
             removing the risk of scalding for the user.   All the internal parts of the body, including the spout,   is engaged
             If the HW supply fails, the CW flow rate is likewise   for the majority of DELABIE's mixers & taps for basins
             reduced.                                  are completely smooth, reducing biofilm attachment
                                                       and making it easier to treat.
            Securitouch technology                     For more information see page 10.
            Securitouch technology provides increased safety
            for superior comfort.                      Low volume of standing water in the body
            The whole mechanism on certain models is insulated,   The majority of DELABIE's mixers have been
            preventing any risk of burns when touching the mixer.  specifically designed to reduce the volume of
            For more information see page 13.          standing water in the body and thus significantly
                                                       reduce the risk of bacterial development. In effect,
                                                       water flows from the inlets to the cartridge via narrow   Temperature stability
            COMFORT                                    tubes which can only hold a limited volume of water.
                                                       The risk of bacterial proliferation is reduced.
            Temperature stability
            • SECURITHERM thermostatic mixers ensure
             stable temperatures regardless of pressure    WATER AND ENERGY SAVINGS
             and flow rate variations in the system. They respond
             immediately to any changes.               The majority of DELABIE's basin mixers are fitted
            • SECURITHERM EP mixers compensate for     with flow rate limiters set at 4 or 5 lpm at 3 bar.
                                                       They offer significant water and energy savings while
             the variations in CW and HW pressure at the inlets.    guaranteeing optimal comfort for the user.
             They ensure that the water temperature at the outlet
             remains stable for the user, removing the risk    30-year warranty against any manufacturing defects.   Body with smooth interior
             of scalding. For more information see page 12.  50 years repairability.
            • DELABIE's mechanical mixers are fitted with
             an exclusive solution which effectively reduces
             temperature variations if there are pressure
             variations in the system.
             However, these mechanical mixers do not have
             the precision of thermostatic or EP mixers and they
             are not fitted with automatic anti-scalding safety.
             They provide an intermediate economic solution.
            Reduced risk of Hot Water/Cold Water cross flow                                       BIOSAFE spout outlet
            On the new generation of DELABIE's mechanical
            mixers, the HW can only flow back into the CW
            supply (or vice versa) if the pressure differential
            between the inlets is greater than 1 bar.
            Therefore, the risk of cross flow between the HW
            and CW is very small, unlike other mixers.                                                          YEAR
            As a result, the risk of bacterial proliferation is reduced.
            Moreover, this solution removes the need for non-
            return valves to be installed.                                                            WARRANTY









                                                                                        Mixers & taps for washbasins  35