Page 37 - Water_Controls_for_Healthcare
P. 37
Mixers for washbasins /
ANTI SCALDING SAFETY BIOSAFE: INFECTION CONTROL
Maximum temperature limiter BIOCLIP removable mixers BIOSAFE
All DELABIE's mixers are supplied with a pre-set for cleaning/disinfection
maximum temperature limiter. The user cannot Since they are in contact with water, the internal
increase the temperature above the maximum set surfaces of mixers and taps are exposed to bacterial
temperature, reducing the risk of scalding. proliferation.
The mixers in the BIOCLIP range provide simple
Automatic anti-scalding failsafe solutions to fight against the spread of germs inside
• SECURITHERM thermostatic technology ensures and on the outside of mixers and taps, and against
immediate hot water (HW) shut-off if the cold water the spread of infectious bacteria by hand. MIXERS & TAPS FOR WASHBASINS
(CW) supply fails. If the CW supply fails, They allow the interior to be cleaned completely
the European standard EN 1111 allows a slight leak - the only way to remove biofilm effectively - and
of HW (0.10L/10 seconds). an easy way to disinfect the mixer, for preventative
With DELABIE's thermostatic mixers the HW or curative reasons, to fight against bacterial
shut-off is complete (with no trickle of water). development effectively.
If the HW supply fails, DELABIE's SECURITHERM
mixers also shut off the CW supply. Body with smooth interior
• SECURITHERM pressure-balancing technology, Most mixers and taps have bodies and spouts with
known as EP, ensures instant and automatic safety. rough interiors. As a result, they provide niches where
If the CW supply fails, the HW flow rate is reduced, bacteria can adhere. Maximum temperature limiter
removing the risk of scalding for the user. All the internal parts of the body, including the spout, is engaged
If the HW supply fails, the CW flow rate is likewise for the majority of DELABIE's mixers & taps for basins
reduced. are completely smooth, reducing biofilm attachment
and making it easier to treat.
Securitouch technology For more information see page 10.
Securitouch technology provides increased safety
for superior comfort. Low volume of standing water in the body
The whole mechanism on certain models is insulated, The majority of DELABIE's mixers have been
preventing any risk of burns when touching the mixer. specifically designed to reduce the volume of
For more information see page 13. standing water in the body and thus significantly
reduce the risk of bacterial development. In effect,
water flows from the inlets to the cartridge via narrow Temperature stability
COMFORT tubes which can only hold a limited volume of water.
The risk of bacterial proliferation is reduced.
Temperature stability
• SECURITHERM thermostatic mixers ensure
stable temperatures regardless of pressure WATER AND ENERGY SAVINGS
and flow rate variations in the system. They respond
immediately to any changes. The majority of DELABIE's basin mixers are fitted
• SECURITHERM EP mixers compensate for with flow rate limiters set at 4 or 5 lpm at 3 bar.
They offer significant water and energy savings while
the variations in CW and HW pressure at the inlets. guaranteeing optimal comfort for the user.
They ensure that the water temperature at the outlet
remains stable for the user, removing the risk 30-year warranty against any manufacturing defects. Body with smooth interior
of scalding. For more information see page 12. 50 years repairability.
• DELABIE's mechanical mixers are fitted with
an exclusive solution which effectively reduces
temperature variations if there are pressure
variations in the system.
However, these mechanical mixers do not have
the precision of thermostatic or EP mixers and they
are not fitted with automatic anti-scalding safety.
They provide an intermediate economic solution.
Reduced risk of Hot Water/Cold Water cross flow BIOSAFE spout outlet
On the new generation of DELABIE's mechanical
mixers, the HW can only flow back into the CW
supply (or vice versa) if the pressure differential
between the inlets is greater than 1 bar.
Therefore, the risk of cross flow between the HW
and CW is very small, unlike other mixers. YEAR
As a result, the risk of bacterial proliferation is reduced.
Moreover, this solution removes the need for non-
return valves to be installed. WARRANTY
Mixers & taps for washbasins 35