Page 49 - Water_Controls_for_Public-Commercial
P. 49

Time flow basin controls /


        HYGIENE                                   EXCEPTIONAL WATER
        AND INFECTION CONTROL                     AND ENERGY SAVINGS: 85%

        Automatic timed shut-off, with no manual contact  Exceptional water savings
        DELABIE’s time flow mixers and taps shut off   Compared to conventional mixers and taps,
        automatically once the push-button has been pressed    DELABIE’s time flow mixers and taps offer maximum
        and the valve has opened.                 water savings. They ensure the manager’s water bills
        No manual contact after washing prevents    can be reduced whilst preserving user comfort.
        the spread of germs by hand.              • Automatic shut-off and split delivery                             BASINS
                                                    The mixer or tap shuts off automatically after   Hygiene and infection control
        Hygienic flow straightener                   approximately 7 seconds of flow.
        Unlike conventional aerators, DELABIE’s flow   DELABIE’s time flow mixers and taps remove
                                            ®
        straighteners are specially made from Hostaform ,    the risk of waste through negligence.
        a material that is highly scale-resistant    The AB anti-blocking system available on certain
        (build-up of scale is 10 times slower).     models, prevents the valve from being blocked
        They minimise water retention and the build-up of dirt,   in the open position.
        and prevent the spread of germs.            The flow time is reduced to the necessary minimum
                                                    (wetting, rinsing).
        PEX flexible hoses
        These flexible hoses will withstand the thermal    • Flow rate regulated at 3 lpm
        and chemical shocks undertaken in public    DELABIE’s time flow mixers and taps are regulated
        and commercial buildings for preventative or curative   at 3 lpm. The flow rate remains constant regardless   Optimised time flow
        treatments against the development of bacteria.  of pressure variations in the system.
                                                    The flow rate is pre-set at 3 lpm at 3 bar. However,
                                                    it can be adjusted from 1.4 (see environmental labels)   Conventional   DELABIE
                                                    to 6 lpm.                                  water controls  water controls
        DESIGN                                                                                   9 lpm   3 lpm
                                                  Energy savings                                 0%      85%
        Commercial environments and design        DELABIE’s time flow mixers and taps operate
        DELABIE's products, known for their endurance    completely autonomously with no need for an electrical
        and reliability, have a timeless design.    supply. They do not consume any power at all.
        The diversity of the product range fits in perfectly    The significant hot water savings provided by
        with any commercial installation.         DELABIE’s mixers and taps also result in energy savings.
        In an office building or a shopping centre it is paramount
        that the product design fits in with its surroundings.    Ecological
        In prison, products must be resistant and secure:   DELABIE's time flow mixers and taps are made
        concealed mechanisms, streamlined design, etc.  from materials that are 100% recyclable which
                                                  ensures that the products receive the best ecological   4.8L  0.7L
        Design without constraints                assessment in their category.
        Aesthetic products are subject to less vandalism                                        32 sec.  14 sec.
        as they are better respected.             Environmental labels
        The smooth shape of the mixers and taps reduces    The water and energy saving performance    Water savings per use
        the build-up of dirt and facilitates cleaning.    of DELABIE’s time flow mixers and taps means that
        Easy but secure access to the control mechanisms   the buildings achieve the highest performance
        provides easy maintenance.                standards for international rating schemes such
                                                  as LEED, BREEAM or HQE.
                                                  For more information see page 8.




                                                  COMPARISONS OF WATER CONSUMPTION
                                                  Conventional controls and DELABIE time flow controls comparison

                                                                                                        Water
                                                   Flow rate  Wetting       Soaping       Rinsing     consumption
                                                                                                        4.8L
                                                                  5 sec.        20 sec.       7 sec.
                                                      9L                                               32 sec.

                                                                                                        0.7L
                                                                  7 sec.                      7 sec.
                                                      3L
                                                                                                       14 sec.












                                                                                                      Basins  47
   44   45   46   47   48   49   50   51   52   53   54