                               TECHNICAL SOLUTIONS                       SPECIFICALLY DESIGNED FOR
                               FOR ALL CONSTRAINTS                       COMMERCIAL ENVIRONMENTS

                               Public and commercial buildings have different   Resistant to intensive use and vandalism
                               requirements depending on the place of installation   DELABIE’s time flow mixers and taps are specifically
                               and type of user. DELABIE has developed specific   designed to withstand intensive use as well as
                               products to respond to a variety of challenges   voluntary and involuntary vandalism.
                               (improving comfort, avoiding waste, user safety, etc.).  The mixer and tap bodies are made from brass,
                                                                         fitted with shock-resistant mechanisms.
          Soft technology:     Soft technology: soft-touch operation     The reinforced fixings will stand up to intensive use.
          soft-touch operation
                               DELABIE has developed time flow mixers and taps    Streamlined designs prevent unwanted removal.
                               with soft-touch operation. Soft technology allows    For areas that require tamperproof installations,
                               all users (children, the elderly or people with reduced   there are recessed and cross wall versions which have
                               mobility) to use the mixers and taps with no effort   mechanisms that cannot be accessed by the user.
                               required.
                               TEMPOSOFT 2, TEMPOMIX and TEMPOMIX 3      Superior endurance
                               models require half the effort to operate compared    The time flow mechanisms in DELABIE mixers and taps
                               to conventional taps/mixers.              are hard-wearing. The hydraulic timing system
                                                                         with a calibrated groove is self-cleaning, which extends
                               AB anti-blocking system: waste prevention  its lifespan to over 500,000 operations.
                               To avoid abuse and waste, TEMPOSTOP (models 1 to 4),   There is no metal-metal or metal-plastic friction,
                               TEMPOMIX 2 and TEMPOMIX 3 models can be fitted   ensuring reliable and durable timing.
          AB anti-blocking system
                               with an AB anti-blocking system.          DELABIE’s mixers and taps perform to the highest
                               This prevents the valve from being blocked in the open   standards. Each model is subjected to endurance tests
                               position. Water will not flow unless the push-button    under extreme conditions in endurance laboratories.
                               is released.
                                                                         Easy to install
                               Temperature selection                     For a quick activation and comfort with no splashing
                               Mixer versions (MIX) of DELABIE’s time flow taps   all DELABIE's time flow mixers and taps are pre-set
                               are available. They offer the user additional comfort   at 3 lpm at 3 bar. They can, however, be adjusted
                               by allowing them to choose the water temperature.   from 1.4 (see environmental labels) to 6 lpm.
                               Temperature adjustment is done via the single control   They are supplied with a pre-set maximum
                               (TEMPOMIX and TEMPOMIX 3) or using the side lever   temperature limiter to save time during installation,
          Vandal-resistant     (TEMPOMIX 2 and TEMPOSOFT MIX 2 and       and can be adjusted by the installer.
                               TEMPOSTOP MIX 4).
                                                                         Minimal servicing
                               Anti-scalding safety                      Flow straighteners and mechanisms are made from
                               DELABIE's time flow mixers are supplied with    scale-resistant materials (Hostaform ).
                                                                                                     ®
                         YEAR  a pre-set maximum temperature limiter that can be   The self-cleaning mechanisms are protected by filters.
                               adjusted during installation. The user cannot increase
                               the temperature above the maximum set temperature,
                                                                         The spare parts are standardised to ensure quick
                               reducing any risk of scalding.            Simple to maintain
              WARRANTY
                                                                         and easy replacement by maintenance staff.
                               Technical characteristics                 The whole of the system is integrated within
                                                                         an interchangeable cartridge without removing
                               Operating pressure  1 - 5 bar, 3 bar recommended  the tap. For the mixer versions, non-return valves
                                                                         are integrated into the flexibles.
                               Pressure differential    ∆P < 1 bar
                               HW / CW                                   30-year warranty against any manufacturing defects.
                         YEARS  Temperature limiter*    Adjustable       50 years repairability.
                                                        55°C max
                               HW supply
            REPAIRABILITY      Adjustable flow rate     1.4 lpm - 6 lpm

                               Time flow                 7 seconds
                                                   TEMPOSOFT 2, TEMPOMIX,
                               Soft-touch technology
                                                       TEMPOMIX 3
                                                  TEMPOSTOP, TEMPOSTOP 2,
                               Anti-blocking system   TEMPOSTOP 3, TEMPOSTOP 4,
                                 R ec ommended installation   TEMPOMIX 2, TEMPOMIX 3
                               Recommended installation
                                                       110 200mm
                               height for wall-mounted ed
                               heigh t  f or  w all-moun t  above washbasin
                               taps
                               taps / mixers
                               * Depending on model