TEMPOFIX 3 with TEMPOFLUX 3 fire retardant frame systems for direct flush /




                                                               INTUMESCENT COLLAR
                                                               AND FIRE PROTECTION SET
                                                               Box sealed in the event of a fire


















                                                                              ACCESS TO MECHANISM
                                                                              AND STOPCOCK
                                                                              FROM THE FRONT
                                                                              Easy to maintain
                                                                              Space saving in the service duct







                                                                              INTUMESCENT COLLARS
                                                                              Supply and outlet pipes sealed in the
                                                                              event of a fire


                  Ø 210MM SOIL PIPE
                    Effective flush





                                                                                                                     CISTERN-LESS   WCs






           Featured product: TEMPOFIX 3 self-supporting fire retardant frame system with TEMPOFLUX 3 time flow direct flush system (ref. 565065DE + 763000)

        The French by-law dated 25 June 1980 specifies safety rules to   With DELABIE's fire retardant solution, the installation of the
        reduce the risk of fires and panic in public and commercial buildings.    TEMPOFIX 3 guarantees:
        This specifically concerns buildings with accommodation such as   • A space saving solution which is practical and looks good whilst
        hotels, care homes and hospitals.                     being fire retardant for 60 minutes.
                                                             • Easy maintenance from the front (behind the control plate)
        If drilling > 75mm in a fire retardant partition (e.g. for a pipe),
        the building must have an adequate device to prevent the   without the need for access to a service duct.
        spread of fire to other areas.                        • Suitable for walls 53 to 105mm.

        « Section 3. Pipes with a diameter larger than 75 millimetres and   Fire retardant solution CF 60 min - EI60 complies with fire safety
        less than or equal to 315 millimetres must be flame retardant    regulations for public and commercial buildings. (Tests carried out by
        for 30 minutes where they transect the walls in public and   Firelab laboratories certified by the COFRAC and meeting ISO 834).
        commercial buildings with the exception of horizontal pipes which
        can be fire resistant for 15 minutes. ».              The UK Regulatory Reform (Fire Safety) Order 2005 sets out
                                                             the guidelines for keeping premises safe and preventing fires.
        Source: Article CO 31 in the French by-law from 25 June 1980
        approving general safety rules against the risk of fires and panic
        in public and commercial buildings, modified by the by-law dated
        26 June 2008.